Maytag Dryer Error Code L2
Low or no line voltage — heater cannot turn on
The most common cause of the L2 error on a Maytag dryer is one 240V breaker leg tripped (~45% of cases); start with: reset the circuit breaker.
What Does Error Code L2 Mean on a Maytag Dryer?
Low or no line voltage — heater cannot turn on.
L2 (also shown as LO) fires when the control board senses that one of the two 240V supply legs is missing or the incoming voltage is too low to energize the heating element. The motor may still run on the surviving leg, so the drum tumbles while clothes stay cold. This distinguishes L2 from element or thermistor faults like F31, which involve the heater circuit itself rather than the incoming supply. The board is reporting a power-delivery problem external to the dryer.
What Causes Error Code L2?
Here are the most common causes in order of frequency. Start with the most likely cause before moving to the next:
- 1 One 240V breaker leg tripped 45% of cases
- 2 Loose connection at breaker or outlet 30% of cases
- 3 House wiring / supply fault 25% of cases
How to Fix Maytag Dryer Error Code L2
- 1
Reset the circuit breaker
Fully switch the dryer's double breaker off then on — both legs must be live.
- 2
Check the outlet and cord connection
Confirm the power cord is fully seated and the terminal block is tight.
🔩 Multimeter⚠️ Unplug before checking the terminal block. - 3
Have the supply inspected
Persistent L2 after resetting points to a house wiring or breaker fault.
⚠️ Electrical supply faults should be inspected by an electrician.
How to Reset Error Code L2
Reset both legs of the breaker and restart. Check the cord and terminal block if L2 persists.
Note: If the error returns after resetting, the underlying issue has not been resolved. Work through the fix steps above.
Did this guide fix your appliance?
✓ Thanks — your feedback helps us improve this guide for the next person.
Thanks for letting us know. If the steps above didn't work, see when to call a professional.
What went wrong? (one tap helps us fix this guide)
✓ Noted — we'll use this to improve the guide.
When to Call a Professional
If the breaker and cord are good and L2 persists, have an electrician check the 240V supply.
Related Error Codes
Same Code on Other Brands
Error code L2 appears on these other brands too. See every brand that shows L2 →
Find Replacement Parts
Use these links to find the exact replacement parts for your Maytag Dryer:
External links — ApplianceErrors.com is not affiliated with these retailers.
More Maytag Dryer Error Codes
Frequently Asked Questions
Can I keep using my Maytag Dryer when error L2 appears? +
What most commonly causes L2 on a Maytag Dryer? +
L2 keeps coming back after a reset — what should I check next? +
How much does it cost to fix Maytag Dryer error L2? +
Which Maytag Dryer models show error L2? +
Sources & References
- • Maytag Product Help — official manufacturer documentation
- • Our editorial & verification policy
Content verified against manufacturer service documentation. Last verified: July 19, 2026.