LG Dryer Error Code dH
High temperature error — drum temperature exceeded safe limit
The most common cause of the dH error on a LG dryer is severely blocked exhaust duct (~55% of cases); start with: clean vent system thoroughly.
What Does Error Code dH Mean on a LG Dryer?
High temperature error — drum temperature exceeded safe limit.
The dH code fires when the control board reads drum or exhaust temperatures above the safe operating limit, typically via the thermistor working alongside the high-limit thermostat. Restricted airflow lets heat build up faster than it dissipates, tripping the safety threshold. Unlike the flow-check codes D90/D95 that flag restriction by monitoring dry time, dH reflects an actual measured overtemperature, and unlike a blown thermal fuse it usually still allows the drum to run until the fault registers.
What Causes Error Code dH?
Here are the most common causes in order of frequency. Start with the most likely cause before moving to the next:
- 1 Severely blocked exhaust duct 55% of cases
- 2 High-limit thermostat failure 25% of cases
- 3 Heater stuck on (relay failure) 20% of cases
How to Fix LG Dryer Error Code dH
- 1
Clean vent system thoroughly
Clean lint filter, full duct run, exterior cap.
🔩 Dryer vent brush kit ($15–$35) - 2
Test high-limit thermostat
Test for continuity after cleaning. Tripped thermostat = replace.
🔩 LG high-limit thermostat ($10–$25) - 3
Test thermal fuse
Blown fuse = no heat but motor runs.
🔩 LG thermal fuse ($8–$20)
How to Reset Error Code dH
After clearing vent and replacing failed components, unplug 5 minutes before restarting.
Note: If the error returns after resetting, the underlying issue has not been resolved. Work through the fix steps above.
Did this guide fix your appliance?
✓ Thanks — your feedback helps us improve this guide for the next person.
Thanks for letting us know. If the steps above didn't work, see when to call a professional.
What went wrong? (one tap helps us fix this guide)
✓ Noted — we'll use this to improve the guide.
When to Call a Professional
If vent is clear and thermostats are fine but overheating persists, heating element relay has stuck closed.
Related Error Codes
Same Code on Other Brands
Error code dH appears on these other brands too. See every brand that shows dH →
Find Replacement Parts
Use these links to find the exact replacement parts for your LG Dryer:
External links — ApplianceErrors.com is not affiliated with these retailers.
More LG Dryer Error Codes
Frequently Asked Questions
Can I keep using my LG Dryer when error dH appears? +
What most commonly causes dH on a LG Dryer? +
dH keeps coming back after a reset — what should I check next? +
How much does it cost to fix LG Dryer error dH? +
Which LG Dryer models show error dH? +
Sources & References
- • LG Support — Help Library — official manufacturer documentation
- • Our editorial & verification policy
Content verified against manufacturer service documentation. Last verified: June 10, 2026.