Maytag Oven Error Code F3-E2
Oven over-temperature — exceeded safe operating limit
The most common cause of the F3-E2 error on a Maytag oven is temperature sensor failure causing runaway heating (~40% of cases); start with: turn off circuit breaker immediately.
What Does Error Code F3-E2 Mean on a Maytag Oven?
Oven over-temperature — exceeded safe operating limit.
F3-E2 fires when the ERC reads an oven cavity temperature above its safe ceiling — typically over about 575°F during normal cooking. The board compares the RTD sensor's resistance against expected values; a shorted sensor, a bake relay welded closed, or wiring feeding continuous element power all produce runaway heating. The control cuts all heat and locks out use. It differs from F3-E0/F3-E1, which flag an open or shorted sensor circuit rather than an actual measured over-temperature condition.
What Causes Error Code F3-E2?
Here are the most common causes in order of frequency. Start with the most likely cause before moving to the next:
- 1 Temperature sensor failure causing runaway heating 40% of cases
- 2 Bake relay on ERC board stuck in closed position 35% of cases
- 3 Wiring fault causing continuous power to heating element 15% of cases
- 4 Self-clean cycle runaway 10% of cases
How to Fix Maytag Oven Error Code F3-E2
- 1
Turn off circuit breaker immediately
Do not attempt to use the oven again until the fault is diagnosed. Allow the oven to cool fully — at least 1 hour.
⚠️ FIRE HAZARD — do not open the oven door or use the oven until diagnosed. - 2
Test temperature sensor after cooling
Disconnect and test the oven temperature sensor (should read ~1,080 ohms). A failed open or shorted sensor can cause the ERC board to drive the heating element continuously.
🔩 Multimeter - 3
Replace sensor if out of spec
If sensor reads correctly, the bake relay on the ERC board has stuck closed.
🔩 Maytag oven temperature sensor ($20–$50) 🔩 Maytag oven ERC board ($120–$300)
How to Reset Error Code F3-E2
Turn off circuit breaker. Do not use until fault is diagnosed by a professional.
Note: If the error returns after resetting, the underlying issue has not been resolved. Work through the fix steps above.
Did this guide fix your appliance?
✓ Thanks — your feedback helps us improve this guide for the next person.
Thanks for letting us know. If the steps above didn't work, see when to call a professional.
What went wrong? (one tap helps us fix this guide)
✓ Noted — we'll use this to improve the guide.
When to Call a Professional
F3-E2 is a safety event. Have a qualified technician diagnose the oven before returning it to service.
Related Error Codes
Same Code on Other Brands
Error code F3-E2 appears on these other brands too. See every brand that shows F3-E2 →
Find Replacement Parts
Use these links to find the exact replacement parts for your Maytag Oven:
External links — ApplianceErrors.com is not affiliated with these retailers.
More Maytag Oven Error Codes
Frequently Asked Questions
Can I keep using my Maytag Oven when error F3-E2 appears? +
What most commonly causes F3-E2 on a Maytag Oven? +
F3-E2 keeps coming back after a reset — what should I check next? +
How much does it cost to fix Maytag Oven error F3-E2? +
Which Maytag Oven models show error F3-E2? +
Sources & References
- • Maytag Product Help — official manufacturer documentation
- • Our editorial & verification policy