Broan-NuTone Range Hood Error Code E02
Fan motor failure — motor not running
The most common cause of the E02 error on a Broan-NuTone range hood is fan motor winding failure (open circuit) (~55% of cases); start with: check the motor connector.
What Does Error Code E02 Mean on a Broan-NuTone Range Hood?
Fan motor failure — motor not running.
The range hood control board is not detecting the fan motor running at all. The motor has failed electrically, or the connection between the board and motor has been lost.
What Causes Error Code E02?
Here are the most common causes in order of frequency. Start with the most likely cause before moving to the next:
- 1 Fan motor winding failure (open circuit) 55% of cases
- 2 Wiring connector between board and motor disconnected 25% of cases
- 3 Control board motor output circuit failed 15% of cases
- 4 Motor thermal fuse blown 5% of cases
How to Fix Broan-NuTone Range Hood Error Code E02
- 1
Check the motor connector
Disconnect power. Locate the motor connector on the control board (typically a 2–3 pin connector). Disconnect and firmly reseat. Check for any burned or corroded pins.
- 2
Test motor windings
Disconnect the motor connector. Test resistance across the motor leads — most Broan blower motors read 3–15 ohms when healthy. Open circuit (OL) = failed motor.
🔩 Multimeter - 3
Check the motor thermal fuse
Some Broan motors have an inline thermal fuse in the motor lead. Test continuity — zero resistance is good, open circuit means the fuse blew and needs replacement.
🔩 Multimeter 🔩 Broan motor thermal fuse ($8–$15) - 4
Replace the blower motor assembly
If motor windings are open, replace the complete blower/motor assembly.
🔩 Broan range hood blower motor ($80–$180)⚠️ Disconnect circuit breaker before any motor work.
How to Reset Error Code E02
Check motor connector. Disconnect circuit breaker 15 minutes. Test motor windings.
Note: If the error returns after resetting, the underlying issue has not been resolved. Work through the fix steps above.
Did this guide fix your appliance?
✓ Thanks — your feedback helps us improve this guide for the next person.
Thanks for letting us know. If the steps above didn't work, see when to call a professional.
What went wrong? (one tap helps us fix this guide)
✓ Noted — we'll use this to improve the guide.
When to Call a Professional
If new motor and E02 persists, the control board motor output circuit has failed — replace the control board.
Related Error Codes
Same Code on Other Brands
Error code E02 appears on these other brands too. See every brand that shows E02 →
Find Replacement Parts
Use these links to find the exact replacement parts for your Broan-NuTone Range Hood:
External links — ApplianceErrors.com is not affiliated with these retailers.
More Broan-NuTone Range Hood Error Codes
Frequently Asked Questions
Can I keep using my Broan-NuTone Range Hood when error E02 appears? +
What most commonly causes E02 on a Broan-NuTone Range Hood? +
E02 keeps coming back after a reset — what should I check next? +
How much does it cost to fix Broan-NuTone Range Hood error E02? +
Which Broan-NuTone Range Hood models show error E02? +
Sources & References
- • Broan-NuTone Support — official manufacturer documentation
- • Our editorial & verification policy
Content verified against manufacturer service documentation. Last verified: June 10, 2026.